Glass Seal
ODL Doorglass uses premium components to become certified by the IGCC as meeting the requirements of ASTM E 2190 is a standard test protocol for evaluating insulating glass (IG) performance, durability, and longevity. There are three main parts to the standard.
High Humidity Test
Samples
are subjected to high humidity and temperature with the objective of forcing
moisture into the sealed air space in an IG unit. Specimens are tested for
42 days and subjected to 95% +/- 5% relative humidity.
Accelerated Weather Cycling
Simulates
weather cycling from hot to cold extremes with moisture added during the
hot cycle. Specimens are tested for 63 days and subjected to 252 cycles.
Volatile Fog Test
Tests
to show that components, or trapped impurities, will not out-gas a volatile
fog, which could result in a deposit on the interior glass surface.
No fog must be visible at arm's length.
ASTM E 2190 is a harmonized standard adopted by the U.S. and Canada.
![]()